Products 09 Applications 06Resources Case studies 06 About 01 FAQ 25 Request a quote RFQ Send a BOM
HomeFAQ

What buyers ask before the first order.

Short answers, written the way we would answer them on a call. If the question is not here, the allocation desk answers in under four hours.

25Questions
4 hShortage answers
24 hBOM quotes

We are an authorized distributor of master-control ICs and electronic components based in Shenzhen. We price and source complete BOMs, cover allocation shortages, buy and resell excess and obsolete inventory, and inspect and document every lot before it ships. Franchised lines run alongside authorized channel sourcing, and every quote says which is which.

One piece for samples on most lines, and one reel or one cut-tape length for production. MOQ is set per part number and per packing format, and it appears on the quotation rather than being negotiated after the order.

Within 24 hours on a working day for a BOM of up to 400 lines. Shortage lines sent to the allocation desk get a first answer within four hours, which may be "covered", "alternate proposed" or "not coverable at your date".

Source vetting, lot and date-code verification, visual inspection under magnification, X-ray on open-market lots, and electrical sampling where the package allows. Anything that fails is returned to the supplier — it is not passed on to the customer with a discount.

Yes. We compare datasheet parameters — pinout, peripheral map, ratings, temperature grade and package — then send the proposed alternate with the differences written down. Nothing is substituted without your engineering team approving it first.

Yes, on discretes, power and most IC lines. The remaining quantity, date code and lot are marked on the bag, and the original reel label is photographed into the shipment record.

Worldwide, ex-Shenzhen and ex-Hong Kong. DDP and DAP terms are available, export documentation is handled in-house, and duty is included in the landed-cost figure when you ask for it.

T/T in advance for first orders, Net 30 for approved accounts, and Net 60 for programme customers on a blanket order. Credit review takes two working days and is done once, not per shipment.

Yes. AEC-Q100 and Q101 lines are quoted with the qualification grade stated, PPAP level 3 packages can be prepared for automotive programmes, and medical shipments carry lot records plus a certificate of conformance.

Yes. Send the list with quantities, date codes and packaging. We quote within two working days, handle the export paperwork, and pay against verified receipt rather than against a promise of stock.

Match the bit width to the processing load: 8-bit for simple control and low-power tasks, 16-bit for mixed control and basic math, 32-bit for complex firmware, communication stacks and signal processing. Check core frequency, memory, peripherals and package rather than bit width alone.

Use an LDO for small current, a close input-output voltage and low-noise analog or RF supply. Use a DC-DC converter for higher current, a wide voltage gap or battery-powered efficiency. Many boards combine both: a switching rail steps the voltage down, and an LDO post-regulates the quiet analog supply.

Bandwidth must cover the signal frequency with headroom above the closed-loop gain; slew rate must handle the fastest output swing. Check gain-bandwidth product, offset voltage, noise and supply voltage against the waveform the load expects, not the chip name alone.

Propagation delay is the time between the input crossing the threshold and the output switching. It sets how fast a level trip or over-current flag reacts. Compare it against the response time the protection or detection loop requires.

RS-485 reaches roughly 1,200 m at low baud rate; distance drops as the data rate rises. Standard transceivers support about 32 unit loads per segment, while reduced-load parts allow more nodes. Verify nodes, baud rate and cable length before selecting the transceiver.

CAN suits distributed control with message arbitration, error framing and multi-node robustness in vehicles and machinery. RS-485 suits simple multi-drop serial links over longer distance with a UART interface. Choose on protocol, arbitration needs and the existing communication stack.

Flash stores firmware and large non-volatile data; EEPROM stores small non-volatile settings that are rewritten often; SRAM holds working data while powered. Choose on density, write endurance, interface and whether the data must survive a power-off.

Isolation voltage is the barrier withstand rating between the two sides. Compare it with the continuous working voltage, channel count and direction, and any reinforced or safety isolation the application requires. Also check supply voltage and data rate.

Resolution sets the smallest detectable step in bits; the sampling rate must be at least twice the highest signal frequency and usually higher to preserve bandwidth. Also check input range, channels, reference, noise and interface before locking the part.

Resolution, settling time or update rate, output range and channels define the analog output. Also check reference accuracy, glitch, supply voltage and interface; match the converter to the waveform update rate the control loop needs.

LED drivers use constant-current outputs to set brightness per channel; PWM dimming modulates duty cycle to adjust intensity without changing forward current. Choose channel count, output current, supply headroom and interface such as I2C, SPI or parallel.

Match the drain-source voltage to the bus voltage with margin; keep RDS(on) low enough to limit conduction loss and heat. Balance gate charge, package thermal rating and gate-driver strength, since a lower RDS(on) can mean higher gate charge.

Surface-mount packages suit automated assembly and dense boards; through-hole suits high-power, mechanical stress or hand-assembled builds. Match body, lead pitch, pin count and footprint between alternate parts, and check the reflow profile for the chosen package.

Compare pinout, peripheral map, ratings, temperature grade and package against the datasheet, then list the differences for engineering approval. An alternate is not confirmed until the engineering team signs off; nothing is substituted without that approval.

Source and lot are verified against records, then marking and date code are inspected under magnification; open-market lots may be X-rayed or electrically sampled. Failed lots are returned to the supplier, and lot, date code and inspection record stay attached to the shipment.

Still unanswered

Ask the allocation desk directly.