| Aspect | Operational amplifier | Comparator |
|---|---|---|
| Purpose | Linear amplification, buffering and filtering | Voltage level detection and threshold crossing |
| Output | Linear analog signal swinging within the rails | Digital high or low level |
| Feedback | Usually closed-loop with feedback network | Open-loop; no linear feedback |
| Response | Limited by settling time and slew rate | Limited by propagation delay |
| Best fit | Signal conditioning, sensors and filters | Threshold detection, over-current and zero-crossing |
How to decide
Use an op-amp when the output must follow the input continuously with gain, filtering or buffering. Use a comparator when the circuit only needs a digital decision: over-voltage flag, zero-crossing detection, or a level trip. A comparator run in a linear feedback loop will not behave like an op-amp, and an op-amp used as a fast threshold detector will usually be slower and less stable than a dedicated comparator.